55M4300CCE00 Rev A
and set the correct configuration in the normal working mode. Additional information
regarding the current boom output sequence is displayed if relevant.
After pressing
“
”
to accept the duty to be calibrated the display shows:
Single reel installations: xxx.xx
. is the maximum working main boom length for this
duty as measured by the extension sensor. This value is usually to the top of the last
telescoping section or manual section and does not include extension fly jibs etc. The
default value will be dimension CL2 or CL2MR, press
“
“
repeatedly to accept this
value. If the boom is to be used at a maximum or fixed length other than the default
use
“
”
or
“
”
to edit this number to the required value. Once the last number is
entered press
“save”
to confirm the value and move to the next step.
Setting the number of length steps:
The display now shows:
The number of length steps represents the number of different boom lengths that will
be used during this calibration process, the number of points selected will directly affect
the calibration time and eventual system performance. More points mean a longer
calibration sequence but with improved performance. Select the number of points from
the following table but note that these figures are only intended as a guide and can be
set as required (up to a maximum of 7) to enable calibration lengths to coincide with
rated boom lengths. This number of points includes the shortest and longest lengths for
the duty, which are mandatory.
Summary of Contents for i4300