55M4300CCE00 Rev A
4
OPTIONS
“Limits setting” parameters
This menu contains the approach warning gaps for all the limits that can be set by the
operator in normal mode. This menu is replaced by “rotation data” if a slew encoder is
fitted.
After selecting “limits setting” from the main calibration menu the screen will show:
Set the approach gap for each limit in turn, angle approach gaps are in degrees, length,
radius and height gaps are set using the calibration units. Remember to press
“save”
once all the data is entered.
“Users ID” Setting user pass codes
This feature is only used if password protection is set to ON. It is a list of password
numbers used to log into the i4300 on startup. Where this feature is not used the
default login number is “99999”.
Navigate through the calibration menu using
“
”
or
“
”
to highlight “users id” and
press
“
”
to enter.
Scroll down to the first “0” entry and press
“
”
to highlight the value for editing, (0
indicates an unset value and is not a valid login number) change the 5 digit number to
the required code and press
“save”
to accept the change, press
“
”
to return to the
main calibration menu. There are 100 different code numbers available to set including
the default value.