55M4300CCE00 Rev A
Telescopic band to be calibrated
None
Up to 6m (20ft)
6-10m (20-30ft)
10-14m (30-45ft)
14-18m (45-60ft)
Over 18m (60ft)
Minimum of points
2 (minimum)
3
4
5
6
7 (maximum)
Use
“
”
or
“
”
to edit this number and press
“save”
to confirm the value and move to
the next step.
If more than two lengths have been entered the display now shows:
Where
length 2
is the second calibration length to be specified.
The first and last lengths will automatically be set to the minimum and maximum values
specified for calibration and other calibration lengths will default to evenly distributed
lengths calculated by the system.
Use
“
”
or
“
”
to change the default value of
length 2
if required, then press
“save”
to
confirm the value and move to the next step.
Specified lengths should coincide with rated boom lengths where possible although not
all rated boom lengths need to be specified. Specified lengths must include lengths at
which the boom telescoping sequence changes. Where no intermediate boom lengths
are shown in the crane capacity chart, use the default lengths chosen by the system.
Enter the remaining lengths as prompted ensuring that each new calibration length is
larger than the preceding one and less than the maximum length.