55M4300CCE00 Rev A
3)
Press
“
”
, the display will change to show the first calibration
screen.
4)
With just the hook suspended, accurately measure the actual
radius of the hook from the centre line of slew of the machine.
5)
Use
“
”
or
“
”
to adjust the “Corr” value until the displayed
radius equals the measured radius. Note: a positive value for “Corr” will increase
the indicated radius. Press
“
”
to accept the change and move to the second
calibration screen.
6)
Carefully lift the test load until it is just clear of the ground.
Accurately measure the actual radius of the suspended load from the centre line
of slew of the machine.
7)
Use
“
”
or
“
”
to adjust the “Corr” value until the displayed
radius equals the measured radius. Press
“
”
to accept the change, the system
will save the calibration, press
“
”
return to the main calibration menu.
8)
Carefully set the test load on the ground.