SECTION 10: L
EG
M
OUNTING
49 of 154
FIGURE 36: Assemblin
g
Le
g
s for Horizontal Air Handlers
CURB ANGLE
A
AIR HANDLER
INTERMEDIATE BOTTOM PLATE
(BOLTS TO 2 CORNER LEGS)
ACCESS
DOOR
1/2"x 1-5/8"
SLOTTED HOLES
CORNER SUPPORT LEGS
4 - REQUIRED
CONTROLS
RIGHT
INTERMEDIATE SUPPORT LEGS
REQUIRED ON ALL CURB ANGLE FIELD JOINTS
(2 CORNER LEGS BOLTED TOGETHER)
CORNER BOTTOM PLATE
(BOLTS TO CORNER LEG)
A
FOR MODEL 4073-4089
(8) - 3/8 X 1" BOLTS
(8) - 3/8 FLANGE NUTS
(8) - 3/8 FLAT WASHERS
MANUFACTURER
PROVIDES FOR EACH LEG:
(12) - 3/8 X 1" BOLTS
FOR MODEL 4024-4066
(12) - 3/8 FLANGE NUTS
(12) - 3/8 FLAT WASHERS
CURB ANGLE
ON UNIT
SECTION
VIEW A-A
Models 4024-4066
HORIZONTAL LEG
NOTE:
Leg mounts to underneath side of channel curb.
LEG
HEIGHT
Formed 10Ga.
Galvanized Channels
Model 4024-4049: 4"
Models 4054-4066: 6"
LEG TOP PLATE
A-A
CURB ANGLE
ON UNIT
SECTION
VIEW A-A
HORIZONTAL LEG
NOTE:
Leg mounts to inside of curb angle. Allow top of
leg to rest against curb angle before tightening bolts.
LEG
HEIGHT
Structural Angle
Model 4073: 3"
Models 4080/4089: 4"
NOTE:
To shorten legs, consult factory.
Le
g
Hei
g
hts
in
cm
24
61
36
91.4
48
121.9
60
152.4
72
182.9
84
213.4
96
243.8
Summary of Contents for 4044
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 73: ...SECTION15 VIBRATION ISOLATION 65 of 154 FIGURE 52 Curb Mounted Roof Curb Roof Curb...
Page 109: ...SECTION19 ELECTRICAL 101 of 154...
Page 110: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 102 of 154...
Page 111: ...SECTION19 ELECTRICAL 103 of 154...
Page 112: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 104 of 154...
Page 113: ...SECTION19 ELECTRICAL 105 of 154...
Page 114: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 106 of 154...
Page 115: ...SECTION19 ELECTRICAL 107 of 154...
Page 116: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 108 of 154...
Page 117: ...SECTION19 ELECTRICAL 109 of 154...
Page 118: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 110 of 154...
Page 119: ...SECTION19 ELECTRICAL 111 of 154...
Page 121: ...SECTION 20 DIRECT FIRED BURNER 113 of 154 FIGURE 71 Midco HMA 2A Burner...
Page 122: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 114 of 154...
Page 125: ...SECTION 20 DIRECT FIRED BURNER 117 of 154...
Page 126: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 118 of 154...
Page 127: ...SECTION 20 DIRECT FIRED BURNER 119 of 154 20 3 Honeywell UV Flame Detector...
Page 160: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 152 of 154...
Page 161: ...SECTION 27 THE RAPID 4000 SERIES WARRANTY 153 of 154...
Page 162: ...4000 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 154 of 154...