The flue system is what makes the fireplace function.
The fireplace will not function optimally if it does not
have the correct and necessary flow in the flue system.
Please consult national/local regulations before
installing the flue system. It must be ensured that the
flue terminal’s position is in accordance with national
building regulations.
This fireplace may be installed with either a roof
terminal (C31), a wall terminal (C11), or a flexible system
through an existing chimney (C91). The fireplace may
only be installed using a balanced flue (also known as
balanced flue system) in the way stated by RAIS. The
RAIS fireplace is approved with the Exodraft fan system.
The flue pipes recommended by RAIS have been
approved together with the fireplace and the fireplace
may only be installed using these:
MANUFACTURER
SYSTEM
ADAPTER
FLUE SIZE
FLUE TYPE
Ontop
Metalotherm US system No adapter needed
Ø130/200
Natural Draught
Ontop
Metalotherm USD
system
No adapter needed
Ø130/200
Natural Draught
Müllink & Grol
Multi-Vent system
Adapter needed
Ø130/200
Natural Draught
Poujoulat
DUOGAS system
Adapter needed
Ø130/200
Natural Draught
Jeremias
TWIN-GAS system
Adapter needed
Ø130/200
Natural Draught
Exodraft
RHGC
No adapter needed
Ø100/150
Forced Draught
The joints on the flue pipes must be sealed and secured
against separation using locking bands or screws.
The fireplace is supplied with a spigot prepared for the
interior fitting of a flue pipe with a diameter of 130/200
mm.
The safety distance from the flue pipe to flammable
materials must be at least 50 mm.
When using a wall outlet, always go straight up 0.5
metres before introducing a 90-degree bend. Please
follow the instructions in the balanced flue manual.
For installation instructions for the flue system, please
follow the separate manual for installation of the
balanced flue. Scan the QR code at the top of the
page to read the manual online.