GB
Ø12 mm 3/8” gas inlet – Only if the flexible line is not used
PROCEDURE
1. Remove the strips holding the flexible gas lines
and wires together and place the parts carefully
under the fireplace. Make sure that no cables are
disconnected.
2. Connect your gas supply to the GV60 Combination
Valve’s flexible inlet line. The thread on the GV60
Combination Valve is 12 mm 3/8’.
Secure against leaks in all gas connections made.
Make sure that the gas is correctly connected.
Always install a stopcock and a measuring stud
before the GV60 Combination Valve. The stopcock
should be placed closest to the GV60 Combination
Valve.
Ø8 mm
Ø8 mm -> Ø12 mm
Ø12 mm
Compression ring
3/8”
WARNING!
Do not twist or hard bend the flexible gas lines from the GV60 Combination Valve. Make sure that the flexible gas lines are
not stressed, and not to damage the gas lines or couplings on the GV60 Combination Valve.
INSTALLATION
GAS CONNECTION
INSTALLATION