21
GB
INSTALLATION
ARRANGING THE CERAMIC LOGS
When arranging the ceramic logs and the embers layer
in the combustion chamber, it is important that they
do not cover the pilot flame and its thermocouple, and
ember material must not be placed under the pilot
guard.
Both thermocouples must be kept free of the embers
layer. Do not cover the holes in the main burner (see
the circles).
When commissioning or servicing the fireplace, it must
be ensured that the cross ignition (from the pilot flame
to the main burner) functions, and that ignition occurs
easily with the secondary burners.
Pilot flame
2
nd
thermocouple
for the main burner
WARNING!
It is very important that you follow this manual when positioning ceramic logs and the embers layer in the fireplace.
Failure to carry this out correctly will result in a flame profile that is less than optimal. Incorrect placement of the logs can
lead to a dangerous situation.
NOTE!
The measurements on the following photos are taken
from the edge of the base plate
. See photo below.
cm