![RAIS Visio 100 RD Installation Manual Download Page 17](http://html1.mh-extra.com/html/rais/visio-100-rd/visio-100-rd_installation-manual_3556300017.webp)
17
GB
INSTALLING THE BURNER
If the burner is not installed on delivery, please follow
these steps to fit the burner.
Make sure that the burner fits the required gas type.
The gas type for the burner is described on the side
of the box which it arrives in. Check that the injectors
correspond to gas type and that the air settings are
correct.
The air settings for the burners varies between the
gas types. Make sure that the correct air settings
have been made, if not, please make the necessary
adjustments.
Follow the guide below for air setting natural gas or
LPG.
INSTALLATION
AIR SETTINGS FOR NATURAL GAS
AIR SETTINGS FOR LPG
The airplate for the main burner needs to be set on
half (see the arrow).
The venturis for the secondary burners needs to be
fitted with a two covering plates. One full plate and
one plate with a small hole.
The airplate for the main burner needs to be set on
fully open (see the arrows).
The venturis for the secondary burners needs to be
fully open with no covering plates installed.