![RAIS Visio 100 RD Installation Manual Download Page 45](http://html1.mh-extra.com/html/rais/visio-100-rd/visio-100-rd_installation-manual_3556300045.webp)
45
GB
INSTALLATION
PURGING THE GAS PIPE
FUNCTIONAL TEST
Read these steps to check the function of the start-up of the gas fireplace.
1. Ignite the fireplace.
2. Check that the pilot flame ignites.
3. Check the pilot flame remains lit.
4. Check that the main burner ignites easily within 20 sec.
5. Check that the cross ignition from the pilot flame to the main burner occurs easily and that the main burner
and pilot flame remain lit.
6. Check that the secondary burners remain lit.
7. Switch off the fireplace completely. The fireplace may only be ignited again after the thermocouple has
cooled down. This will take about 1-2 minutes.
INSTALLATION
When the gas supply is connected for the first time, the
supply lines will be filled with air. The gas supply can
then be purged by unscrewing the inlet pressure tap on
the side of the burner.
NOTE!
When the purging is complete, retighten the “pressure
tap” screws. Check the system for gas leaks.
PURGING THE GAS PIPE
Scan the QR code
to watch a how-to-video
Inlet pressure tap
Outlet pressure tap
Inlet
Outlet
Outlet
Inlet