ERROR CODES ON THE REMOTE CONTROL
TROUBLESHOOTING AND ERRORS
ERROR
CODE
SYMPTOM
POSSIBLE CAUSE
F04
• No pilot within 30 sec.
• Note: After 3 failed ignition sequences F06
is shown.
• No gas supply
• Air in pilot supply line
• No spark
• Reversed polarity in 1
st
thermocouple wiring
F06
• 3 failed ignition sequences within 5
minutes
• Fire is not responding, no pilot flame
• No gas supply
• Air in pilot supply line
• No spark
• Reversed polarity in 1
st
thermocouple wiring
• Incorrect pilot orifice if valve has been converted
from LPG to NG or vice versa.
F09
• Fire is not responding
• No electric control of the fire
• The down arrow button was not pushed during
pairing.
• Receiver and handset are not synced
F40
• Battery icon flashes on handset display
• Low battery in handset
F46
• Fire is not responding
• Intermittent response
• No electronic control of the fire
• No or bad connection between the receiver and
handset
• No power to the receiver
• Low communication range (Main adapter faulty,
handset not communicating with the receiver)
TROUBLESHOOTING AND ERRORS