In addition to the many operating features available in your RME HAWK controller, there
are a number of programmable features as well. (See User Programmable Features, page 4.)
By simply pushing the SETUP key, you can program the following functions. Successive
pushing of the SETUP key will allow you to advance to the next setup feature.
Some of the SETUP functions will be skipped (on successive pushing of the SETUP
key) depending on what you have entered for other previous SETUP functions. The
conditions for which a SETUP function will be skipped are noted below in the description
of the applicable SETUP function.
IMPORTANT: When entering SETUP information the display will change but the
controller will not actually accept the information until Enter or Clear
(for those SETUP functions that accept Clear) is hit.
MASTER VALVE (MV)
Function
Master Valve Used
Type of Master Valve
Pump
Cycle and Soak
Flow Sensor Features
Pipe Size (inches)
Main Line Flow Limit
Unscheduled Flow Limit
Flow Check Delay
Total Gallons
Flow Percentage
Station Upper Flow Limits
Option
Uses, Does Not Use
NC, NO
Uses, Does Not Use
Uses, Does Not Use
On, Off
1, 1.25, 1.5, 2, 3, 4
1-999 GPM
0-999 GPM
1-6 minutes
N/A
5-80%
0-500 GPM
Default
1,2,3,4 (all programs enabled)
NC
(all programs disabled)
(all programs disabled)
Off
1.5 inches
500 GPM
200 GPM
2 minutes
N/A
20%
200 GPM for all stations
Setup Options and Controller Defaults