Section VIII – Maintenance
90 Quincy Vacuum Pump-QSV Series
4. Open the vent plug (VP) of the oil cooler.
5. Connect a hand drill or cordless screwdriver to the oil drain pump (Op).
• Insert the pump shaft into the drill chuck and tighten.
• Open the 3-way ball valve (Do).
• Activate the hand drill to drain the vessel and oil cooler.
• Collect all the oil in an oil waste can.
6. Close the oil drain valve (Do1).
7. Open the drain valve (Do2).
• Activate the hand drill to drain the element and outlet housing.
• Collect all the oil in an oil waste can.
• Close the drain valve (Do2).