Section III - Airlogic Graphic controller
Quincy Vacuum Pump-QSV Series 39
(i)
Service
(ii)
Overview
(iii)
Service plan
(iv)
Next service
(v)
History
Scroll through the items to select the desired item and press the Enter key to see the details as explained
below.
Overview
(i)
Overview
(ii)
Running hours
(iii)
Real time hours
(iv)
Reset
Example for service level (A):
The figures at the left are the programmed service intervals. For Service interval A, the programmed number of
running hours is 4000 hours (upper row) and the programmed number of real time hours is 8760 hours, which
corresponds to one year (second row).
This means that the controller will launch a service warning when either 4000 running hours or 8760 real hours are
reached, whichever comes first. Note that the real time hours counter keeps counting, also when the controller is
not powered.