Section VIII – Problem solving
96 Quincy Vacuum Pump-QSV Series
Problem solving
CAUTION!
Before carrying out any maintenance, repair work or adjustment, stop vacuum pump, close the
isolation valve and wait 3 minutes.
Press the emergency stop button and switch off the voltage.
Vent the vacuum pump by opening the plug on the cover of the air inlet filter.
For location of components, see sections:
Introduction.
Operation instructions
Maintenance.
Open and lock the isolating switch.
Lock the isolation valve during maintenance or repair.
The operator must apply all relevant Safety precautions.
Before electrical maintenance
CAUTION!
Wait for at least 10 minutes before starting any electrical repairs as dangerous high voltage
remains on the capacitors of the start and speed regulation unit during some minutes after
switching off the voltage.
Faults and remedies, vacuum pump
If the alarm LED is lit or flashes, consult sections Event history menu or Service menu.
Condition
Fault
Remedy
The pump cannot reach
ultimate pressure
Air leakage in the inlet piping
connections
Check for leakages in the inlet filter
assembly and piping. Check sealing
between components
Low oil level
Top-up oil
Oil contaminated
Replace oil
Solenoid-valve malfunctioning
Replace valve
Vacuum pump element out of
order
Consult Quincy
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...