Section VI – Operating instructions
82 Quincy Vacuum Pump-QSV Series
Step
Action
1
Switch on the voltage. Check that voltage on LED (6) lights up.
2
Press start button (1) on the control panel. The vacuum pump starts running and the automatic
operation LED (8) lights up.
3
Open the inlet isolation valve (IV).
6.3 During operation
NOTICE!
Keep the panels closed during operation.
WARNING!
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may start
automatically
.
CAUTION!
When the automatic operation LED (8) is lit, the regulator is automatically controlling the vacuum
pump, i.e. loading, purging, stopping of the motors and restarting
!
Regularly check the oil level during operation.
A few minutes after stopping, the oil level should reach the top of the oil sight glass (Gl).
If the oil level is too low, wait until the vacuum pump has vented. Push the emergency stop button (10) to
avoid the vacuum pump to start unexpectedly. Next, close the inlet isolation valve (IV).
Remove the oil filler plug (FC) and add oil until the level reaches the top of the oil sight glass. Fit and
tighten the plug (FC).
Unlock the emergency stop button (S3), select the
STOP
icon on the display and press reset before
restarting.
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...