Section VI – Operating instructions
Quincy Vacuum Pump-QSV Series 81
• Make sure the pump outlet is not obstructed.
• Fit inlet isolation valve (IV); see section Installation proposal for the position of the valve.
• Close the valve.
• Connect the inlet pipework to the valve.
• Check the oil level, the oil level should reach the top of the oil sight glass (GI).
• If needed, top up the oil via the oil filler plug (FC).
• Take care that no dirt drops into the oil system.
• Provide labels, warning the operator that:
• The vacuum pump may automatically restart after voltage failure (if activated, consult Quincy).
• The vacuum pump is automatically controlled and may be restarted automatically.
• The vacuum pump may be remotely controlled.
• Check the programmed settings. Consult section Programmable settings.
• Verify that the inlet control valve and the blow off solenoid valve are connected to the required
compressed air supply.
• Start and run the vacuum pump for a few minutes. Check that the vacuum pump operates normally.
• Open the inlet isolation valve (IV).
6.2 Starting
Control panel Airlogic Graphic
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...