Section VIII – Problem solving
Quincy Vacuum Pump-QSV Series 97
Condition
Fault
Remedy
The pump cannot reach stated
vacuum
Air consumption exceeds air
delivery of vacuum pump
Check equipment connected
Clogged air filter element
Replace the filter
Too high pressure drop between
process and pump inlet
Check the process lines for correct size
and for leakage. Correct if necessary
Low oil level
Top up oil
Oil contaminated
Replace oil
Solenoid valve malfunctioning
Replace valve
Vacuum pump element out of
order
Consult Quincy
Air leakage
Check the process lines for leakage
Pressure switch trips
Oil separator elements clogged
Have elements replaced
Oil filter clogged
Have oil filter replaced
Discharge clogged
Check couplings and outlet
Bypass valve or oil injection
system clogged
Have bypass valve cleaned or replaced.
Pressure switch out of order
Replace pressure switch
Vacuum pump element outlet
temperature above normal
Oil level too low
Check and correct, see Operation
instructions / During operation
Insufficient cooling air or cooling
air temperature or relative
humidity is too high
Check for cooling air restriction or improve
ventilation of the vacuum pump room.
Avoid recirculating of cooling air. If
installed, check capacity of vacuum pump
room fan
Oil cooler clogged
Clean cooler
Oil filter clogged
Replace oil filter
Scavenge line clogged
Clean scavenge line
Electronic thermostatic valve
malfunctioning
Have valve tested
Degraded oil
Check service intervals, see Preventive
maintenance schedule
Temperature of pressure air too
high
Check process air temperature
Vacuum pump element out of
order
Consult Quincy
Converter fault codes
If a problem is detected by the converter, a specific code (Main motor converter alarm) will appear on the
graphic regulator display, together with a fault code.
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...