Section VII – Maintenance
Quincy Vacuum Pump-QSV Series 93
NOTICE!
After maintenance on the fan and on the coolers:
Remove the loose parts that are used as cover.
Mount the service plate (1) at the fan compartment.
7.7 Oil separator change
CAUTION!
The operator must apply all relevant Safety precautions
.
Procedure
Stop the vacuum pump, close the isolation valve and switch off the voltage.
Wait a few moments for the vacuum pump to vent the vessel.
Open the required service panels.
Unscrew the bolts of the cover of the oil separator tank
Open the cover of the oil separator tank backwards
Remove the oil separator elements (OS) by turning one quarter counter-clockwise
Clean the seat on the shield. Lubricate the gasket of the new oil separator using vacuum pump oil and
screw it into place. Tighten by hand.
NOTICE!
Make sure all separator elements are assembled in the correct position. An arrow is printed on the
cover of the separator elements and the bottom of the shield; all arrows should be pointing in the
same direction after assembly
.
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...