Section V - Options
Quincy Vacuum Pump-QSV Series 77
6. Chlorides (Cl-)
Chloride ions will create pitting corrosion on stainless steel. Their concentration should be limited,
depending from the RSI value.
RSI < 5.5
5.6 < RSI < 6.2
6.3 < RSI < 6.8
6.9 < RSI < 7.5
7.6 < RSI
Cl- (ppm)
200
350
500
350
200
7. For energy recovery systems, the limit is 100 ppm.
Sulphate (ppm)
Type of cooling system
Standard
Energy recovery
Single pass
< 1000
< 200
Recirculating (with tower)
< 1000
not applicable
Closed loop
< 400
< 200
8. Iron and Manganese
Dissolved iron (ppm)
Dissolved manganese (ppm)
Type of cooling system
Standard
Energy recovery
Standard
Energy recovery
Single pass
< 1
< 0.2
< 0.2
< 0.05
Recirculating (with tower)
< 1
not applicable
<
0.2
not applicable
Closed loop
< 1
< 0.2
< 0.2
< 0.05
The values in bold are rejection limits.
9. Copper
Copper (ppm)
Type of cooling system
Standard
Energy recovery
Single pass
< 1
< 0.2
Recirculating (with tower)
< 1
not applicable
Closed loop
< 1
< 0.2
10. Ammonium
The limit of 0.5 ppm is a rejection limit. The limitation only applies for copper containing systems.
11. Suspended solids
Large particles (size > 10 μm) should not be present as they can be filtered out. Small particles
(< 0.5 μm) are not taken into account. For particles between 0.5 μm and 10 μm, the following limits apply:
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...