Section III - Airlogic Graphic controller
44 Quincy Vacuum Pump-QSV Series
The upper and lower limit of the setting is shown in grey, the actual setting is shown in black. Use the Scroll keys to
modify the settings as required and press the Enter key to accept.
If necessary, change the other settings as required in the same way as described above.
Indirect stop: occurs when the pressure decreases to the pre-set Indirect stop setpoint (=setpoint minus Indirect
stop level). The motor will decelerate to minimum speed and the inlet valve will close.
Both settings (Indirect stop level and direct stop level) are programmable, see section Programmable settings.
3.12 Event history menu
Control panel
(1)
Scroll keys
(2)
Enter key
(3)
Escape key
Menu icon, Event History
Function
To call up the last shut-down and last emergency stop data.
Summary of Contents for QSV 2200
Page 1: ...Quincy Oil sealed rotary screw vacuum pumps QSV 2200 QSV 2700 QSV 3200 Instruction Manual...
Page 2: ......
Page 4: ...This page intentionally left blank...
Page 14: ...Section II General description 14 Quincy Vacuum Pump QSV Series Open view front Open view back...
Page 61: ...Section IV Installation Quincy Vacuum Pump QSV Series 61 Installation 4 1 Dimension drawings...
Page 62: ...Section IV Installation 62 Quincy Vacuum Pump QSV Series 4 2 Installation proposal...
Page 122: ...Notes 122 Quincy Vacuum Pump QSV Series...
Page 123: ......
Page 124: ...www quincycompressor com No 6996 0227 39 2017 09 Printed in USA...