background image

Residential Indoor Gas

Tankless

Water Heater

Warning: This water heater is not suitable

for use in manufactured (mobile) homes!

The purpose of this manual is twofold: one, to provide the
installer with the basic directions and recommendations
for the proper installation and adjustment of the water
heater; and two,

to the owneroperator,

to explain the

features, operation, safety precautions,maintenance and
troubleshooting of the water heater.

This manual also

includes a parts list.

It is imperative that all persons who are expected to install,
operate or adjust this water heater read the instructions
carefully so they may understand how to perform these
operations. If you don't understand these instructions or
any terms within it, seek professional advice.

Any questions regarding the operation, maintenance,
service or warranty of this water heater should be directed
to the seller from whom it was purchased. If additional
information is required, refer to the section on If You Need
Service.

Do not destroy this manual. Please read carefully and keep
in a safe place for future reference.

Use & Care Manual

With Installation Instructions for the Installer

136,000 BTU Max Input

Recognize this symbol as an indication of Important SafetyInformation!

California Proposition 65 Warning: This product contains chemicals known to the State of
California to cause cancer, birthdefects or other reproductive harm.

WARNING:

If the in formation in these instructions is not followed exactly,

a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this or
any other appliance. To do so may result in an
explosion or fire.

Do not try to light any appliance.
Do not touch any electrical switch; do not

use any phone in your building.

FOR YOUR SAFETY!

WHAT TO DO IF YOU SMELL GAS

Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
Do not return to your home until authorized
by the gas supplier or fire department.

Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, personal injury, or death.
Refer to this manual. Installation and service
must be performed by a qualified installer,
service agency or the gas supplier.

-

-

-

ON/OFF

UP

DOWN

F

Output Temp

Set Temp

Error Code

Summary of Contents for Residential Indoor Gas Tankless Water Heater

Page 1: ...ion Instructions for the Installer 136 000 BTU Max Input Recognize this symbol as an indication of Important SafetyInformation California Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer birthdefects or other reproductive harm WARNING If the in formation in these instructions is not followed exactly a fire or explosion may result causing prope...

Page 2: ...he appliance Proof of the original purchase date is needed to obtain service under the warranty Staple sales slip or cancelled check here READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your water heater properly A little preventive care on your part can save you time and money over the life of your water heater You ll find many answers to common problems in the...

Page 3: ...ire explosion or asphyxiation from carbon monoxide never operate this water heater unless it is installed properly and has an adequate air supply for proper operation Be sure to inspect the flue terminal for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection DANGER IN...

Page 4: ...l panel was set at 110 F before it was shipped from the factory o The illustration to the bottom left illustrates the control panel and how to adjust the water temperature Notice When this water heater is supplying general purpose hot water requirements for use by individuals a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of...

Page 5: ...r LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look and smell for gas leaks Use a soapy solution to check all gas fittings and connections Bubbling at a connection indicates a leak that must be corrected When smelling to detect a gas leak be sure to...

Page 6: ...o prevent property damage personal injury or loss of life California Law requires that residential water heaters must be braced anchored or strapped to resist falling or horizontal displacement due to earthquake motions For residential water heaters up to 52 gallon capacity a brochure with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacra...

Page 7: ... fire which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc If the water heater is installed in a garage it should be installed so that the direct ignition system and main burner are no less than 18 inches above the garage floor Raising the gas fired water heater will reduc...

Page 8: ...r combustion and ventilation air must be made A confined space is one having a volume of less than 50 cubic feet per 1000 Btuh of the aggregate input of all appliances within that space The air must be supplied through two permanent openings of equal area One is to be located within 12 above the floor and the other is to be located within 12 below the ceiling The minimum net free area of each open...

Page 9: ...oors additional water pressure 0 44 psi ft must be ensured The measurement should be calculated by the distance between the water inlet of the water heater ground level to the hot water faucet upper floor level Well water systems should be set at a range of 50 60 psi When the water is supplied from a water supply tank the height of the tank and the diameter of the pipes and their relation to water...

Page 10: ...lief valve and to prevent water damage If the relief valve on the system discharges periodically a problem exists and service to the water system is required Notice Notice Notice Relief Valve Notice The above illustrates a pressure only relief valve If local codes require a combination temperature and pressure relief valve be installed an extension piece may be needed Install a Check Valve between...

Page 11: ...sion could result in hazardous operating conditions 11 Gas Supply The supplied Manual Gas Appliance Shutoff Valve must be installed at the gas connection of the water heater at the time of installation see diagram to the left The branch gas supply line to the water heater should be clean 3 4 black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi r...

Page 12: ...on monoxide NEVER operate the water heater unless it is properly vented and has adequate air supply for proper operation as outlined in the Venting section of this manual WARNING Use UL approved Category III Stainless Steel vent material only No other vent material is permitted WARNING Refer to page 7 for clearances to combustible material MAXIMUM VENT LENGTH The system will not operate if there i...

Page 13: ...the adapter over the water heater collar before proceeding Adjust clamp as needed With an alcohol wipe clean inside surface A of adapter and outside surface of B of heater collar Apply 1 4 wide bead of high temperature silicone 500 F around outside of heater collar B Slide adapter end A down over heater collar B as far as it will go o Vent Adapter Tighten the clamp around the collar Inspect the in...

Page 14: ... water heater Additional Considerations 14 Horizontal Vent Terminal Location Do Not install vent terminal under any patio or deck To help prevent moisture from freezing on walls and under eaves do not locate vent terminal on the side of a building with prevailing winter winds Do Not terminate vent pipe directly on brick or masonry surfaces Use a rust resistant sheet metal backing plate 2 x 2 feet ...

Reviews: