DLT4000 SCSI Interface
8-70 DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem
8.4.9.10 MODE SELECT Changeable Parameters
The following table lists the changeable mode parameters and their minimum and
maximum values allowed. See the previous definitions for the units that are used.
Parameter rounding is supported for all parameters except the block descriptor length.
Table 8-5
Changeable Mode Parameters
Page: Parameter
Default
Minimum
Maximum
Header: Buffered Mode, Device Specific Byte
1
0
1
Block Descriptor Length
08h
00h
08h
Block Descriptor: Block Length
2.6 GB and 6.0 GB mode
10.0 GB, 15.0 GB, 20.0 GB, 30.0 GB and
40.0 GB mode
0
0
0
0
40000h
FFFFFFh
Read-Write Error Recovery (01h): PER Bit
0
0
1
Control Mode (0Ah): RLEC
0
0
1
Data Compression (0Fh): DCE
1
0
1
Disconnect-Reconnect (02h): Maximum Burst
Size
0080h
0000h
FFFFh
Disconnect-Reconnect (02h): DTDC
0
0
3
Device Configuration (10h): Write Delay Time
C8h
Fh
1964h
Device Configuration (10h): SEW
1
0
1
Device Configuration (10h): Select Data
Compression Algorithm
1
0
1
Summary of Contents for DLT 4700
Page 1: ...DLTTM 4000 DLTTM 4500 DLTTM 4700 Cartridge Tape Subsystem Product Manual...
Page 2: ......
Page 160: ...Firmware Update From Tape 7 18 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 215: ...DLT4000 SCSI Interface DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 8 55...
Page 304: ...DLT4000 SCSI Interface 8 144 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 342: ...Sense Key Information C 6 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 359: ...Index DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 7...
Page 360: ...Index 8 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...