Troubleshooting Guide for the DLT4500/DLT4700 Mini-Library
6-2 DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem
_________________________ NOTE
Do not press the Load/Unload button to abort any function of the
DLT4500/DLT4700 mini-library. Press [Ctrl/Y]
or [Ctrl/C]
instead.
___________________________________________________________
See Chapter 4 for more information on the functions of the DLT4500 OCP
buttons.
Table 6-1
DLT4500 OCP Button Conditions
If you want to
…
…
First, ensure the
…
…
Then you can press
this button
…
…
Select another slot in the
magazine
•
Magazine contains at
least two cartridges
•
LDR RDY displays
Select
Load the selected
cartridge into the tape
drive
•
Magazine contains at
least one cartridge
•
LDR RDY
displays
Load/Unload
Return the selected
cartridge to its original
slot in the magazine
DRV RDY
displays
Load/Unload
Clear a magazine or
loader error
ERR MAG or ERR LDR
displays
Load/Unload
Open the door or unload
the cartridge from the
drive and open the door
LDR RDY
displays
Open
Summary of Contents for DLT 4700
Page 1: ...DLTTM 4000 DLTTM 4500 DLTTM 4700 Cartridge Tape Subsystem Product Manual...
Page 2: ......
Page 160: ...Firmware Update From Tape 7 18 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 215: ...DLT4000 SCSI Interface DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 8 55...
Page 304: ...DLT4000 SCSI Interface 8 144 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 342: ...Sense Key Information C 6 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 359: ...Index DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 7...
Page 360: ...Index 8 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...