
Configuring and Operating the DLT4700 Mini-Library
5-10 DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem
Density Select Example
If you have loaded a tape with a prerecorded 2.6 GB density and you use the Density
Select button to select 10.0/15.0 GB density, the following should happen:
•
The 2.6 indicator remains lit
−
density has not changed yet and the steady indicator
indicates recorded tape density
•
The 10.0/15.0 indicator blinks
−
density change is pending
•
Density Override indicators
When a write from BOT occurs, the following should happen:
•
2.6 turns off
•
10.0/15.0 indicators steady
•
Density Override remains lit
Summary of Contents for DLT 4700
Page 1: ...DLTTM 4000 DLTTM 4500 DLTTM 4700 Cartridge Tape Subsystem Product Manual...
Page 2: ......
Page 160: ...Firmware Update From Tape 7 18 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 215: ...DLT4000 SCSI Interface DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 8 55...
Page 304: ...DLT4000 SCSI Interface 8 144 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 342: ...Sense Key Information C 6 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...
Page 359: ...Index DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem 7...
Page 360: ...Index 8 DLT4000 DLT4500 DLT4700 Cartridge Tape Subsystem...