CubiScan 125 Service Manual
1 8
Chapter 3
Cleaning
This section describes the procedure used to clean the CubiScan 125. The CubiScan 125 should be
cleaned as often as needed to maintain optimum performance.
Cleaning the Gate Filters
While dust won’t normally interfere with operation, the gate filters should be cleaned routinely to
prevent the possibility of interference.
To clean the gate filters, use a clean, damp (if needed), microfiber cloth. Use water to dampen the
cloth;
do not clean the gate filters with a solvent as this could cause damage
.
Cleaning the Glass Platform
To clean the glass platform, remove it from the CubiScan 125. Clean both sides of the platform
thoroughly with a clean, damp cloth.
If the glass platform is scratched it may interfere with measurements. Remove the glass platform
and try measuring. If this resolves the problem, you may need a new glass platform. Use your
spare glass platform. If you need to order a new platform, please contact Quantronix Technical
Assistance at +1 801-451-7000.
Cleaning the Touchscreen
To clean the touchscreen, moisten a soft cloth with water, then gently wipe the screen clean with
the cloth. Do not spray liquid directly on the touchscreen.
Cleaning the Ultrasound Sensors
To clean the ultrasound sensors, blow dust from the surface or wipe gently with a dry microfiber
cloth. The front of the sensor is delicate. Do not use high pressure air or water lines to clean the
surface and do not touch it with fingers, tools, or brushes. Doing so may result in damage.