Communication Protocol
CubiScan 125 Command Set
CubiScan 125 Service Manual
7 5
Weight Units
This command is used to set the weight units to either English (pounds) or metric (kilograms)
mode.
Zero
This command should be issued periodically to force the CubiScan 125 to perform internal
compensations to adjust to changes in temperature and humidity. This command should only be
issued when the measuring field is free of packages! Never issue this command when a package is
present in the measuring field.
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Wgt. Unit Command
Alpha
(#)
23h
3
1
English or Metric
Alpha
(E/M)
45h or 4Dh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Wgt. Unit Command
Alpha
(#)
23h
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Wgt. Unit Command
Alpha
(#)
23h
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
End of Text
Control
(ETX)
03h