Communication Protocol
CubiScan 125 Command Set
CubiScan 125 Service Manual
6 7
Measure
Receipt of this command causes the CubiScan 125 to measure and weigh the package using the
ultrasound sensors. The CubiScan 125 immediately formats the data collected and transmits it to
the host computer.
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
Acknowledge
Alpha
(A)
41h
4
1
CubiScan/Host
Originated
Alpha
(C/H)
43h or 48h
5
6
City Code
Alpha
000000-ZZZZZ
Z
11
1
Comma
Alpha
(,)
2Ch
12
1
Length Identifier
Alpha
(L)
4C
13
5
Length
Numeric
000.0-999.9*
18
1
Comma
Alpha
(,)
2Ch
19
1
Width Identifier
Alpha
(W)
57h
20
5
Width
Numeric
000.0-999.9*
25
1
Comma
Alpha
(,)
2Ch
26
1
Height Identifier
Alpha
(H)
48h
27
5
Height
Numeric
000.0-999.9*
32
1
Comma
Alpha
(,)
2Ch
33
1
Dimension Unit
Alpha
(E/M)
45h or 4Dh
34
1
Comma
Alpha
(,)
2Ch
35
1
Weight Identifier
Alpha
(K)
4Bh
36
6
Weight
Numeric
000.00-999.99*
42
1
Comma
Alpha
(,)
2Ch
43
1
Dim. Wgt. Identifier
Alpha
(D)
44h
44
6
Dim. Weight
Numeric
000.00-999.99*
50
1
Comma
Alpha
(,)
2Ch