Figure 10-7 The Operation/Element Status Page
Table 10-2 describes the Operation/Element Status screen information displayed.
Field Option
Description
Configuration Page
511000 Rev. F
Partition
The number of the partition where the element is assigned. Depending on
ve up to five
e elevator
1, 2, 3, 4,… 20
how the resources are allocated a single RLS-85XX can ha
partitions while a RLS-8350 can have up to three. When th
expansion option is used, up to four RLS-85XX libraries can be
interconnected for a total of up to 20 potential partitions.
Address
The SCSI address assigned to the element.
Type
Slot, Drive,
Handler, IO Port
The type of element; Slot, Drive, Handler or IO Port.
Location
The physical location of the element.
Full
Yes or No
Indicates if a cartridge is in the location.
Access
he tape drive,
Yes or No
The library can access the cartridge. When a tape is inside t
its present, but not accessible.
Pri. Tag
o the tape
Yes or No
This value is set to Yes when there a barcode label attached t
cartridge.
Label
The value read from the barcode label attached to the tape cartridge.
Source Valid
Yes or No
This value is set to Yes when the source data is valid.
Address Contains the SCSI address of the last storage element from w
cartridge came.
hich the
Location
This item only displays when the value of Source Valid is Yes.
Table 10-2 Operation/Element Status Description