Maintenance
5-5
5.1.3 Changing the Cleaner Felt
If a new Toner Cartridge is inserted you should also check the status of the
Cleaner Felt. The Cleaner Felt is below the top cover (4) and at the right side of
the fuser unit.
If the Cleaner Felt is very dirty, it is advised to replace it. A new Cleaner Felt (6)
is in the box of the Toner Kit.
S
Press first
.
OFFLINE
will be displayed.
S
Open the front (1) and rear (2) cover.
S
Press the lever (3) to open the top cover (4), illustrated below.
S
Now remove the Cleaner Felt (6) by pressing both green levers (5) in
direction of the arrow and lift it, illustrated below.
Note:
The metal bar of the Cleaner Felt might be very hot.
Don´t throw away the Fuser Cleaner Platen!
Continuation next page:
Maintenance
5-6
S
Remove the Cleaner Felt (2) from the Cleaner Platen (1) by pressing the
clamp (3) on both sides of the platen.
S
Mount the new Cleaner Felt (2) with the eye in the middle (4) onto the lug (5)
and press the clamp (3) on both sides onto the Cleaner Platen (1).
S
Insert the new Cleaner Felt (2) including the Cleaner Platen (1).
S
Close the top, rear and front cover.
Note:
Depending on paper properties it might be necessary to change the
Cleaner Felt more often!