SECTION 5
Pronar T314, Pronar T315, Pronar T316
5.17
FIG. 5.9
Air filter
(1) securing slide lock, (2) air filter cover
DANGER
Before proceeding to dismantle filter, reduce pressure in supply line. While
disengaging filter slide gate, hold cover with other hand. Stand away from filter
cover vertical direction.
Required service actions
¨
Reduce pressure in supply line.
Ö
Reduction of pressuring line may be achieved by pressing the head of
the pneumatic connection to resistance point.
¨
Remove securing slide (1).
¨
Hold the filter cover (2) with the other hand. After removing slide lock, the
cover is pushed off by the spring, in the filter housing.
¨
The insert and the filter body should be carefully washed out and blown
through with compressed air. Assembly should be done in reverse order.