In the event, that the valve stem resists returning to its setting, then the whole
drain valve must be unscrewed and cleaned, or replaced (if it is damaged) -
see section
CLEANING DRAIN VALVE
.
Draining water from air tank:
•
every seven days of use.
5.4.2 CLEANING DRAIN VALVE
DANGER
Before dismantling drain valve release air from tank.
Required service actions
¨
Reduce pressure in air tank.
Ö
Reduction of pressure in tank is achieved by tilting the drain valve
mandrel.
¨
Unscrew valve.
¨
Clean valve, purge with compressed air.
¨
Change copper seal.
¨
Screw in valve, fill air tank, and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).