Pronar T314, Pronar T315, Pronar T316
SECTION 5
5.36
FAULT CAUSE
REMEDY
Insufficient tractor hydraulic
pump output, tractor
hydraulic pump is damaged.
Check tractor hydraulic pump.
Damaged or contaminated
ram cylinder
Check cylinder ram piston
(bending, corrosion), check ram
cylinder for tightness (piston seal),
in case of need repair or replace
ram cylinder.
Excessive cylinder ram
loading
Check and reduce cylinder loading
if necessary
Damaged hydraulic
conduits
Check and ascertain that hydraulic
conduits are tight, not fractured
and properly tightened. If
necessary replace or tighten.
Damaged rotary vane
vacuum pump
Check and follow the instructions
included in the Operator's Manual
of the rotary vane vacuum pump.
Leaking tank
Broken welds, pierced tank
coating – have the slurry tanker
repaired.
Leaking connections
Check connections of damper,
stoppers, relief valve and sight-
glasses. Tighten connection or
replace seals.
Leaking conduits
Check tightness of conduits and
method of their attaching. Replace
or repair.
Problem with achieving
proper overpressure or
negative pressure.
Damaged relief valve,
siphon valve or safety valve
Repair or replace.
Summary of Contents for T314
Page 4: ......
Page 9: ...SECTION 1 BASIC INFORMATION ...
Page 22: ...Pronar T314 Pronar T315 Pronar T316 SECTION 1 1 14 ...
Page 23: ...SECTION 2 SAFETY ADVICE ...
Page 40: ...Pronar T314 Pronar T315 Pronar T316 SECTION 2 2 18 ...
Page 41: ...SECTION 3 DESIGN AND OPERATION ...
Page 53: ...SECTION 4 CORRECT USE ...
Page 68: ...Pronar T314 Pronar T315 Pronar T316 SECTION 4 4 16 ...
Page 69: ...SECTION 5 MAINTENANCE ...
Page 106: ...Pronar T314 Pronar T315 Pronar T316 SECTION 5 5 38 ...
Page 107: ...NOTES ...
Page 108: ... ...
Page 110: ...ANNEX B ...