Unscrew bolts (1) – figure (5.14) fixing the rear gate. Open the gate.
¨
Unscrew two stoppers (4) of side connections (on the left and right side of the
tank).
¨
Unscrew drain plug of the tank.
¨
Clean the tank interior with strong water jet through the side openings and rear
manhole.
Ö
Clean the tank until all sediment accumulated on the bottom and
adhering to the tank walls is rinsed out. Cleaning may be stopped
when clean water flows out through the drain opening.
FIG. 5.13
Rear gate and side connection stopper
(1) rear gate, (2) fixing bolt, (3) hinge, (4) connection stopper
¨
Leave the tank open for as long as possible – minimum 12 hours.
¨
Before entering the tank, prepare breathing apparatus that enables breathing
in air from air cylinder.