40 PRODIGIT
Setting Vsense and load input switching methods, the middle of the 5 digit LCD
Display will show "SENSE", right 5 digit LCD display will show "AUTO" or "ON".
Set Load ON voltage, the middle of the 5 digit LCD display will show "LDon", right 5
Digit LCD display will show setting value, the units is V, The Load ON Voltage set
Range from 0.1V to 25.0V step 0.1V by rotating the setting knob. If the load is greater
Than the input voltage Load ON voltage setting, the Electronic load current begin to
Load on.
Setting Load OFF voltage, the middle of the 5 digit LCD display will show "LDoFF",
Right the 5 digit LCD display will show settings value, the units is V, The Load OFF
Voltage set range from 0.0V to 24.9V step 0.1V by rotating the Setting knob.
If the load input voltage is less than Load OFF setting voltage, the electronic load to
Load off.
Set Load polarity, the middle of the 5 digit LCD display will show "POLAR", right the 5
Digit LCD display "will show + LOAD" or "-LOAD", use the knobs and key settings "+
LOAD" or "-LOAD".