3350F Series Operation Manual 99
5.3.4. CC Mode Operating Instructions
Example: PSU 5 V / 3 A, CC mode, Level HI 3.000A, Level 1.500A
5.3.4.1. These can be selected in turn by pressing the "MODE" key (8), LCD will
Illuminate According to the operating mode is selected CC.
5.3.4.2. Pressing the "Preset" Key (13) once will cause the Button to illuminate.
5.3.4.2.1. Pressing the LEVEL key (12) LED once will illuminate, Select LEVEL Hi,
Adjusted by the rotary knob and arrow key (21) can be read from the
Right display during Setting 3.000 A.
5.3.4.2.2. Pressing the LEVEL key (12) LED once will off, Select LEVEL Lo,
Adjusted by the Rotary knob and arrow key (21) can be read from
The right display during setting 1.500A.