4-1
4
Preen Program
The ADG-P series can be remote-controlled via a PC. Preen offers remote control
software Preen Program which allows users to easily setup the remote operation
without further need of programming. The software provides all the setting and
measuring functions of the ADG-P touch screen HMI for users to set the parameters
and monitor the output measurement. In addition, Preen Program also provides the
function of waveform preview and output report generation to save the output data
in CSV or TXT file for easy viewing and saving the both setting and measurement data
conveniently.
4.1
RS-485 /RS-232 interface connection
The standard communication interface of ADG-P is RS-485, and optional RS-232 and
GPIB. RS-485 is a D89 female connector as shown in Figure 4.1, located on the front
panel next to the touch screen of 30kW/50kW model and on the upper side of the
rear panel of 75kW/100kW model.
Figure 4.1 RS-485 DB9 connector
To remotely control the ADG-P series via RS-485 interface, connect Pin 4 and Pin 6 of
the DB9 connector to a PC, and ensure both side of the line are well connected. Refer
to Figure 4.2 for D89 pin.
Pin
Name
Descriptions
1
NC
No Connection
2
NC
No Connection
3
NC
No Connection
4
RS-485 D+ RS-485 Signal D+
5
NC
No Connection
6
RS-485 D-
RS-485 Signal D-