2.4
Remote Sensing Compensation
The ADG-P series supports optional remote sensing compensation, monitoring the
voltage at the load instead of the output terminals of the product, ensuring the load
receives the product programming voltage by automatically compensating for the
output voltage drop due to cable resistance.
The remote sensing compensation connector is located below the DC output
terminal as shown in Figure 2.4.
Connect “S
-
“and “S+” of the
remote sensing
compensation connector to the corresponding terminals at the load as shown in
Figure 2.5. This feature is enabled when the connection is completed.
Notices for the connection leads:
1.
As part of the feedback circuit of the product, the leads must have a low
resistance in order to maintain the best performance.
2.
The leads must be shielded twisted pair to minimize external noise interference.
Insulation of the leads used for high voltage model should be taken into
consideration.
3.
The leads need to be connected to the DUT as close as possible.
Figure 2.4 Remote sensing compensation connector