Model
30kW
ADG-P-400-75
ADG-S-400-75
ADG-P-500-60
ADG-S-500-60
ADG-P-640-47
ADG-S-640-47
ADG-P-800-38
ADG-S-800-38
ADG-P-1000-30
ADG-S-1000-30
ADG-P-1600-18
ADG-S-1600-18
50kW
ADG-P-400-125
ADG-S-400-125
ADG-P-500-100
ADG-S-500-100
ADG-P-640-78
ADG-S-640-78
ADG-P-800-63
ADG-S-800-63
ADG-P-1000-50
ADG-S-1000-50
ADG-P-1600-31
ADG-S-1600-31
AC Input
Voltage
3Φ3W + G
380 VAC ± 10%
(Option 200VAC/208VAC/400VAC/415VAC/440VAC/480VAC)
Frequency
47-63Hz
Power Factor
≧
90% at maximum power
DC Output
Line Regulation
≦
0.1%
Load Regulation
≦
0.032%
≦
0.14%
≦
0.132%
≦
0.034%
≦
0.02%
≦
0.05%
Voltage Ripple (RMS)
≦
0.13%
≦
0.109%
≦
0.13%
≦
0.05%
≦
0.08%
Voltage Noise (Peak)
≦
0.88%
≦
1.34%
≦
0.88%
≦
0.29%
≦
0.27%
≦
0.4%
Voltage Slew Rate*1
≦
115ms
≦
280ms
Transient Response*2
≦
4-12ms
Measurement
Voltage Accuracy
0.5% F.S.
Voltage Resolution
0.1V
Current Accuracy
0.5% F.S
Current Resolution
0.1A
Protection
Type
Vin OVP, Vin UVP, OVP, OCP and OTP
OVP Range
5% - 115% from front panel
OVP Accuracy
1% F.S.
OCP Range
5% - 115% from front panel
OCP Accuracy
1% F.S.
General
Efficiency
≧
90%
Remote Sense Limits
3% maximum voltage drop from product output to load
(for product models with output voltage lower than 1000VDC)
Operational Temperature
0°C-40°C
Storage Temperature
-20°C-70°C
Humidity
0-90%(Non condensing)
Isolation
Input to product cover: 2000VAC
Dimension(H×W×D)
380V Input: 1038×600×800 mm
3
/40.8×23.7×31.5 inch
3
200V/208V/480V Input: 1382×600×800 mm
3
/54.4×23.7×31.5 inch
3
Weight
380V Input: approx. 188kg/414.5lbs
200V/208V/480V Input: approx. 388kg/855.4lbs
Table 1.3 Technical Specifications