Chapter 5 Function parameter
54
Ch
ap
ter 5
465.
y0.01
User password
0 to 65535
0
☆
466.
y0.02
Function
parameter group
display selection
Units digit: d group display selection
0: not displays 1: displays
Tens digit: E group display selection(the same
above)
Hundreds digit:b group display selection(the
same above)
Thousands digit:y group display selection(the
same above)
Tens thousands digit:L group display
selection(the same above)
11111
★
467.
y0.03
Personality
parameter group
display selection
Units digit:User‟s customization parameter
display selection
0:not display 1:display
Tens digit :User‟s change parameter display
selection
0:not display 1:display
00
☆
468.
y0.04
Function code
modification
properties
0: modifiable
1: not modifiable
0
☆
5-1-21.
y1 Group -Fault query
No. Code
Parameter name
Setting range
Factory
setting
Chang
e
469.
y1.00 Type of the first fault
0: No fault
1: Inverter unit protection
2: Acceleration overcurrent
3: Deceleration overcurrent
4: Constant speed overcurrent
5: Acceleration overvoltage
6: Deceleration overvoltage
7: Constant speed overvoltage
8: Control power failure
9: Undervoltage
10: Inverter overload
11: Motor Overload
12: Input phase loss
13: Output phase loss
14: Module overheating
15: External fault
16: Communication abnormal
17: Contactor abnormal
18: Current detection abnormal
19: Motor self-learning
abnormal
20: Encoder/PG card abnormal
21: Parameter read and write
abnormal
22: Inverter hardware
abnormal
-
●
470.
y1.01 Type of the second fault
-
●
471.
y1.02 Type of the third(at last) fault
-
●