Chapter 5 Function parameter
63
Ch
ap
ter 5
3.kcommunication command control
Operation panel and communication command control.
4.kterminal block+communication command control
Operation panel
、
terminal block and communication command control.
F0.12
Binding
frequency
source for
command
source
Units digit
Keyboard command binding frequency
source selection
000
☆
Not binded
0
Keyboard set frequency
1
AI1
2
AI2
3
Panel potentiometer
4
High-speed pulse setting
5
Multi-speed
6
Simple PLC
7
PID
8
Communications reference
9
Tens digit
Terminal block command binding frequency
source selection (0 to 9, same as units digit)
Hundreds
digit
Communication command binding frequency
source selection (0 to 9, same as units digit)
Define the combination of 3 operation command channels and 9 frequency reference
channels for easily synchronously switching.
The principle for above frequency source reference channel is same as frequency source
master setting selection F0.03, please see the description of F0.03 function code. The different
running command channel can be bundled with the same frequency reference channel. When
command source has the available frequency source for bundling, in the valid period of command
source , the set frequency source by F0.03 to F0.07 is no longer valid.
F0.13 Acceleration time 1
0.0s~6500s
-
☆
F0.14 Deceleration time 1
0.0s~6500s
-
☆
Acceleration time refers to the required time when the inverter accelerates from zero
frequency to F0.16.
Deceleration time refers to the required time when the inverter decelerates from F0.16 to zero
frequency.
JI500
provides four groups of ac/deceleration time, user can select by using the digital input
terminal DI, as follows:
The first group: F0.13, F0.14; The third group: F7.10, F7.11;
The second group: F7.08, F7.09; The fourth group: F7.12, F7.13.
F0.15 Ac/Deceleration time unit
1 second
0
1
★
0.1 second
1
0.01 second
2
To meet the demand of the various on-site,
JI500
provides three kinds of time unit: 1
second, 0.1 second and 0.01 second respectively.
Note: when modifying the function parameters, the number of decimal places that the four
groups of ac/deceleration time displayed will change displayed, the ac/deceleration time will
change accordingly.
F0.16
Ac/deceleration time reference
frequency
Maximum frequency(F0.19)
0
0
★
Set frequency
1
100Hz
2
Ac/deceleration time refers to the required time from zero frequency to F0.16 or from F0.16
to zero frequency.
When F0.16 selects 1, the ac/deceleration time depends on the set frequency, if the set
frequency change frequently, and the acceleration of the motor is varied, please use with caution.
F0.17 Carrier frequency adjustment as per temperature
NO
0
0
☆