Chapter 5 Function parameter
53
Ch
ap
ter 5
455.
b0.27
Motor parameter auto tunning
0: no operation
1: asynchronous motor
parameters still auto tunning
2: asynchronous motor
parameters comprehensive auto
tunning
11: synchronous motor
parameters still auto tunning
12: synchronous motor
parameters comprehensive auto
tunning
0
★
456.
b0.28
Encoder type
0: ABZ incremental encoder
1: UVW incremental encoder
2: Rotational transformer
3: Sine and cosine encoder
4: Wire-saving UVW encoder
0
★
457.
b0.29
Encoder every turn pulse
number
1 to 65535
2500
★
458.
b0.30
Encoder installation angle
0.00 to 359.90
0.00
★
459.
b0.31
ABZ incremental encoder AB
phase sequence
0: forward
1: reverse
0
★
460.
b0.32
UVW encoder offset angle
0.00 to 359.90
0.0
★
461.
b0.33
UVW encoder UVW phase
sequence
0: forward
1: reverse
0
★
462.
b0.34
Speed feedback PG
disconnection detection time
0.0s: OFF
0.1s to 10.0s
0.0s
★
463.
b0.35
Pole-pairs of rotary
transformer
1 to 65535
1
★
5-1-20.
y0 Group - Function code management
No.
Code
Parameter
name
Setting range
Factory
setting
Chan
ge
464.
y0.00
Parameter
initialization
0: no operation
1: restore default parameter values, not including
motor parameters
2: clear history
3: restore default parameter values, including
motor parameters
4: backup current user parameters
501: restore from backup user parameters
10: Clear keyboard storage area3
11: upload parameter to keyboard storage area 1
12: upload parameter to keyboard storage area 2
21: download the parameters from keyboard
storage 1 area to the storage system 3
22: download the parameters from keyboard
storage 2 area to the storage system 3
0
★