Chapter 5 Function parameter
41
Ch
ap
ter 5
254.
F7.51
AI1 input voltage
protection upper limit
F7.50 to 10.00V
6.8V
☆
255.
F7.52~
F7.53
Reserve
256.
F7.54 Jog mode setting3
Bits:
0: forward
1: reverse
2: determine the direction from the
main termina
Ten bits:
0: restore to the previous state after
jogging
1: stop running after jogging
Hundred bits:
0:recover to the previous deceleration
time after jogging
1: keep the deceleration time the
sameafter jogging
002
☆
5-1-10.
F8 Group - Fault and protection
No. Code
Parameter name
Setting range
Factory
setting
Chang
e
257.
F8.00 Overcurrent stall gain
0 to 100
20
☆
258.
F8.01
Overcurrent stall protection
current
100% to 200%
150%
☆
259.
F8.02
Motor overload protection
selection
0: Invalid
1: Enable
1
☆
260.
F8.03 Motor overload protection gain
0.20 to 10.00
1.00
☆
261.
F8.04
Motor overload pre-alarm
coefficient
50% to 100%
80%
☆
262.
F8.05 Over-voltage stall gain
0 to 100
0
☆
263.
F8.06
Over-voltage stall protection
voltage / energy consumption
brake voltage
120% to 150%
130%
☆
264.
F8.07
Input phase loss protection
selection
Units digit:Input phase loss
protection selection
0: Invalid 1: Enable
Tens digit:contactor actuation
protection
0: Invalid 1: Enable
11
☆
265.
F8.08
Output phase loss protection
selection
0: Invalid
1: Enable
1
☆