Installation
Guide
PS-4660TW
This wire provides a constant 500 mA ground output
while the module is running. This output becomes
active at the same time as the ignition and shuts off
when the module shuts down, e.g.: when the run
time has expired, when the
START/STOP
button has
been pressed, etc. This output can be used to
activate external relays, bypass kits, etc.
10
WHITE
(–) Ground
Out
When
Running
Caution!
If multiple relays or modules are connected
to the ground- out-when-running
wire, make sure
they are diode isolated from one another: feedback
may otherwise occur, causing damage to the vehicle.
This input should be used in vehicles with
negative-
switching
door pins or dome light circuits. Connect
to the dome light wire that tests ground when a door
is open.
11
GREY
(–) Negative
Door input
Caution!
The installer should use
either
the positive
or
the negative door input. Never use both of them
simultaneously.
It is essential that the module be connected in such a
way as will allow each one of the doors to turn off
ready mode:
t h e d r i v e r - s i d e d o o r p i n
d o e s n o t c o n s t i t u t e b y i t s e l f a
s u f f i c i e n t c o n n e c t i o n
.