If the “Temperature Parameters” icon is pressed, Figure 5 will be shown. As shown in
parameter setup, the set value is the desired operating value while the actual value is the current
temperature of the heating zone. The deviation value is the allowable tolerance on the actual value
to the set value before the sealer deviation alarm activates. For example, if the actual value of
heating zone 1 is 10 degrees below the set value and the deviation value is 5 degrees, the deviation
alarm will be activated. The cool down value is the maximum temperature the heating zone sealing
bars must be at during cool down to turn the sealer off. Deviation and cool down value are
adjustable while “Settings” is only allowed to be adjusted by the OEM.
If the “Units” icon is pressed, Figure 6 will be shown. This screen allows the user to change
the parameter units of temperature, pressure, speed and length.