X20AT2402 T/C channel2-
above upper limit
Zone 2 below above
temp upper limit
a. Allow sealer to cool down zone 2 to set value
X20AT2402 T/C channel2-
wire break
Zone 2 thermocouple
wire broken
a. Replace thermocouple in zone 2
X20AT6402 T/C channel1-
below lower limit
Zone 1 back bar below
lower temp lower limit
a. Allow sealer to heat up zone 1 back bar to set
value
X20AT6402 T/C channel1-
above upper limit
Zone 1 back bar below
above temp upper limit
a. Allow sealer to cool down zone 1 back bar to
set value
X20AT6402 T/C channel1-
wire break
Zone 1 back bar
thermocouple wire
broken
a. Replace thermocouple in zone 1 back bar
X20AT6402 T/C channel2-
below lower limit
Zone 1 front bar below
lower temp lower limit
a. Allow sealer to heat up zone 1 front bar to set
value
X20AT6402 T/C channel2-
above upper limit
Zone 1 front bar below
above temp upper limit
a. Allow sealer to cool down zone 1 front bar to
set value
X20AT6402 T/C channel2-
wire break
Zone 1 front bar
thermocouple wire
broken
a. Replace thermocouple in zone 1 front bar
X20AT6402 T/C channel3-
below lower limit
Zone 2 back bar below
lower temp lower limit
a. Allow sealer to heat up zone 2 back bar to set
value
X20AT6402 T/C channel3-
above upper limit
Zone 2 back bar below
above temp upper limit
a. Allow sealer to cool down zone 2 back bar to
set value
X20AT6402 T/C channel3-
wire break
Zone 2 back bar
thermocouple wire
broken
a. Replace thermocouple in zone 2 back bar
X20AT6402 T/C channel4-
below lower limit
Zone 2 front bar below
lower temp lower limit
a. Allow sealer to heat up zone 2 front bar to set
value
X20AT6402 T/C channel4-
above upper limit
Zone 2 front bar below
above temp upper limit
a. Allow sealer to cool down zone 2 front bar to
set value
X20AT6402 T/C channel4-
wire break
Zone 2 front bar
thermocouple wire
broken
a. Replace thermocouple in zone 2 front bar
Zone 1 Pressure Sensor -
lower value exceeded
Zone 1 pressure below
lower limit
a. Allow sealer to increase pressure in zone 1
Zone 1 Pressure Sensor -
upper value exceeded
Zone 1 pressure above
upper limit
a. Allow sealer to decrease pressure in zone 1
Zone 1 Pressure Sensor -
open line
Open pneumatic line on
zone 1 plumbing
a. Investigate plumbing of zone 1 pneumatics
from back control box fitting to seal section
cylinders
Broken Teflon Band Front Front teflon band broken
a. Replace front telfon band
b. See section 4.1 for procedure
Summary of Contents for MPS6100
Page 6: ...MPS6100 ORIGINAL Page vi ISO SAFETY SYMBOLS LOCATION...
Page 7: ...MPS6100 OPERATION MANUAL ORIGINAL Page x MPS6100 OPERATION MANUAL...
Page 27: ...MPS6100 MAINTENANCE MANUAL ORIGINAL Page xii MPS6100 MAINTENANCE MANUAL...
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......