FINAL INSPECTION
To check whether the device is working properly and safely, before it is put into operation, perform the
following checks.
7.1.
Gas tightness
All connections must be tight. Check the connections for gas tightness. The gas control block can be subjected
to a maximum pressure of 50 mbar.
7.2.
Gas Pressure
Burner’s pressure shown on the nameplate of the device, is set at the factory and under no circumstances can
be changed.
WARNING!
You should check the pressure in the home installations, because it may be incorrect. In addition,
check the pressure in the gas block system. The location of the measuring nipple (
P
in) over the gas assembly
shows the picture below. If the pressure is not correct (too high or too low), please contact the gas supplier.
Also, check the output pressure of the gas by connecting the measuring device to the measuring nipple and
compare them with output pressure of the burner written on the nameplate of the device. To connect the
measuring device, unscrew the screw on the test nipple (9 mm) by half a turn and connect the hose.
Photo 3 - Nozzles measuring gas pressure