25
Pay attention to the maximum distance of the gas assembly from the fireplace when placing the
inspection hatch with a gas assembly.
Picture 7 - Maximum distance of the inspection hatch with gas assembly from the fireplace
.
5.9.
The exhaust and combustion air supply system
5.9.1.
General Information
The device is connected to the integrated exhaust and combustion air supply system, hereinafter referred to
as concentric flue system with dimensions of 200mm / 130mm. The concentric flue system might be derived
outside by the side wall of the building as well as the roof. If necessary, you can also use the existing chimney
for the combustion air supply. concentric flue system is designed for indoor use and therefore cannot be used
outside, with the exception of terminals that are made for this purpose. In all these cases you must comply
with regulations in force in the country.
Use the concentric system supplied by Planika. This system has been tested in conjunction with MONROE
series.
WARNING!
Planika company cannot guarantee the proper and safe operation of other concentric
systems, than provided by the manufacturer, and therefore disclaims any responsibility for malfunction of the
system, which may result in incorrect operation of the device MONROE, its damage and violation of generally
understood principles of safety.