15
EN
ENGLISH
ELECTRICAL WIRE DIAGRAM
The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
220-240 V, 50 Hz, 250 W, GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
FUEL INPUT
RATING:
2 KG/H
(4.4 LB/H)
INDEX
W : WHITE
Y : YELLOW
P : PURPLE
R : RED
K : BLACK
G : GREEN
P
P
R
Y
Y
Y
P
K
K
W
G
W
W
W
R R
W
W
W
W
Y
Y
K
W
IGNITER ASSEMBLY /
HD CARTRIDGE HEATER
200 W, 220-240 V
BURN POT
DRAFT FAN
220-240 V, 50 Hz
GROUNDED
POWER CORD
AUGER MOTOR
& FEED SYSTEM
220-240 V, 50 Hz
GROUND
GRILL
PROBE
GRILL PROBE
CONNECTOR
FAST-BLOW FUSE
CONTROL BOARD
*PB700G /PB850G / PB1150G
Model Hopper
*PB550G Model Hopper
LOCATE AND REMOVE
THE TWO SCREWS
OF ACCESS PANEL ON
THE SIDE OF HOPPER.
RELEASE BOTTOM
HOPPER PANEL DOWN
AND SLIDE BACK TO
UNSEAT FROM TAB.
MALE
ADAPTER