15
<Ver. 2.1>
A
Installation conditions
3.2.4 Strain on surface where equipment is installed
1
This display uses glass in its display section. When using a third-party metal fixture, check that strain is 1 mm or
less by the following method.
2
Tightly fit a thread using a force of
φ
0.1psi or less diagonally through the mounting bolt openings on the mounting
surface, as shown in the drawing.
3
Measure distance L of the intersection of the strings in the center section.
The relationship between strain and L is given by Strain = L
×
2.
4
If L is 0, interchange the front and rear positions of two strings and check the distance again. If the value of L is not
0, it is the true value of L. If L is 0 after the position is changed, strain is approximately 0.
Holes for
mounting
bolts
Plasma display-mounting surface
(mounting metal fixture)
Enlarged drawing of the intersectional part A
(showing the part obliquely)
Thread
Right angle
A
a
d
c
b
a
c
d
b
a
d
e
f
c
b
Point e is the center of the thread a-b.
Point f is the center of the thread c-d.
Distance between e and f =
L
Points e and f are indicated in an en-
larged figure for more detailed under-
standing.
Thread
Summary of Contents for PDA-4001
Page 5: ...5 Ver 2 1 Features ...
Page 19: ...19 Ver 2 1 Installation procedure ...
Page 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Page 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Page 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Page 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Page 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Page 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...